blank_1920_347


eGFR (Calculated)

Estimated Glomerular Function Rate (eGFR) is a parameter of prime clinical significance as it is a key indicator of renal function.

eGFR is calculated in conjunction with a patient’s serum creatinine level, taking into account factors such as gender, age, ethnicity to determine the overall efficiency of renal function. The rate of decline in eGFR distinguishes Chronic Kidney Disease (CKD) from Acute Kidney Injury (AKI).

Clinical Details

Becoming more common, chronic kidney disease affects approximately 10% of the population. It is defined as an abnormality in renal function or structure of the kidney, present for at least 3 months.

Patients at high risk of kidney disease are those with diabetes, hypertension, obesity, > 50 yrs of age, acute kidney injury, long term history of OTC medications and family history of chronic kidney disease.

Markers of kidney disease may include: albuminuria (ACR > 3 mg/mmol), haematuria, electrolyte abnormalities due to tubular disorders, renal histological abnormalities, structural abnormalities detected by imaging (e.g. polycystic kidneys, reflux nephropathy) or a history of kidney transplantation. CKD is classified based on the eGFR and the level of proteinuria present.

The Irish Nephrology Society currently recommends classifying Chronic Kidney Disease into five stages.

CKD Stage
eGFR
1 >90ml/min/1.73m2
2 60 – 89ml/min/1.73m2
3 30-59ml/min/1.73m2
4 15-29ml/min/1.73m2
5 <15ml/min/1.73m2

The CKD Heatmap was devised to assist clinicians to risk stratify patients. Patients are classified as G1-G5, based on the eGFR, and A1-A3 based on the ACR (albumin:creatinine ratio) as detailed below:

https://www.researchgate.net/figure/Heatmap-representing-the-risk-for-CKD-progression-according-to-GFR-and-albuminuria_fig1_332389199

 

 

Case Study
At Enfer Medical, we have integrated a cutting-edge and fully automated WASPLab® (Walk Away Specimen Processor) that has significantly enhanced our testing capabilities to ensure the highest of quality when processing patient samples.
blank_532_358
blank_532_358
WASPLab® at Enfer Medical
Our entire microbiology workflow has been optimized using automation and highly sophisticated robots to ensure uninterrupted incubation for rapid bacterial growth and improved turnaround times for patients.
blank_532_358

Our Services

Service
Health & Wellness
General health and wellness testing can include a variety of tests, depending on the needs of the individual or recommendations of
Find Out More
Service
Sexual Health
Regular STI screening facilitates early treatment and reduces the long-term consequences of infection.
Find Out More
Service
Respiratory Health
Rapid early pathogen identification has important treatment and infection control implications. See our range of tests here.
Find Out More
Service
Reproductive & Female Health
Hormonal analysis is hugely beneficial to identifying problems that can arise during the reproductive years.
Find Out More
Service
All Services
View the full suite of services at Enfer Medical here.......
Find Out More
Sample Type &
Volume Required

5mL venous serum or plasma

blank_711_422
blank_336_232
blank_711_422
blank_336_232
blank_727_647
blank_711_422
blank_336_232
blank_711_422
blank_336_232
Transporting
Samples

In addition to the packaging of samples, the transport/delivery of clinical samples to the laboratory is required to be in adherence to all national regulations for the safe transport of biological materials. Enfer Medical provides a fully compliant logistics service, aligned with clients’ testing requirements.

Prompt transport of specimens:
To ensure prompt testing of samples and release of results within the published test turnaround times, samples should arrive to the laboratory by 18:00. Test turnaround time is measured from receipt of the sample at the laboratory until the time the authorised results are reported to users.

Acceptance/Rejection
of Samples

In rare cases specimens may not be suitable for testing on arrival to the laboratory. In that case the sample will be rejected at the receipt stage and the service user will be notified immediately and an explanation as to why the sample could not be processed will be provided. Reasons why samples cannot be processed include but are not limited to:

  • Samples received beyond the stability limits and/or not at the correct temperature indicated for each test.
  • Incorrect sample type received.
  • Leaking samples, sample not received or sample insufficient for analysis as stated below within sample requirements.
  • Non-compliant samples or request forms i.e. those missing sample date information, missing sample test request and/or missing sample site/type information.
  • Samples received without the necessary patient identifiers.
Clients will be provided with guidance on Sample Receipt Anomalies.

Our Services

Service
Health & Wellness
General health and wellness testing can include a variety of tests, depending on the needs of the individual or recommendations of
Find Out More
Service
Sexual Health
Regular STI screening facilitates early treatment and reduces the long-term consequences of infection.
Find Out More
Service
Respiratory Health
Rapid early pathogen identification has important treatment and infection control implications. See our range of tests here.
Find Out More
Service
Reproductive & Female Health
Hormonal analysis is hugely beneficial to identifying problems that can arise during the reproductive years.
Find Out More
Service
All Services
View the full suite of services at Enfer Medical here.......
Find Out More
Result Values:

Quantitative results for eGFR (Calculated) are reported in numeric value in ml/min/1.73m2. Please contact us for more information on the reference ranges used at Enfer Medical.

Critical results are communicated in accordance with the Communication of critical results for patients in the community- national laboratory handbook CSP041/2019

blank_711_422